725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for new albany, oh

Rated 4.9 out of 5 stars based on 9 customer reviews

Quick Response & Excellent Service!

Westin Air continues to exceed my expectations for responsiveness and quality of service! Everyone is extremely friendly, understand and accommodating to help make the situation right! I would highly recommend Westin Air to anyone who wants a reliable, friendly and HONEST HVAC company!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent!

Great experience! Everyone was so nice from scheduling to the technician. Prompt and helpful. Overall an excellent experience and I will recommend them to other!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always a Great Experience

I have known Seth from Westin Air for 4 years and must say he NEVER disappoints! I have complete faith and trust in him that he is taking the best approach to fix my a/c! I highly recommend Westin Air!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick response. Great service.

Called Westin Air for a “bum” furnace on a Monday morning and a tech was there Monday afternoon. Quick assessed the situation, identified the issue and promptly fixed. Would recommend.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Westin Gives Great Service

Worked with Seth today and covered all of needs for my services. I have worked with Westin before and would give high five!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Seth, is does a great job with the service and explaining his service. He is very pleasant and knowledgable re the heating and airconditioning system.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Very pleased with the service and knowledge. Great job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Very professional installation of a humidifier

  • Overall Experience
  • Quality
  • Price
  • Convenience

good service

The service we received was great. Everything that was done was a nice clean job. The price was satisfactory. I apologize for taking so long to respond. I just have a hard time with filling things out. so, sorry again

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for new albany, oh

Nate G.

Nate G. Job Checkin

Two system heating maintenance Basement furnace 21yr old Trane 80% efficient single stage natural gas furnace Pulled and cleaned flame sensor Changed 20x25x4 filter Blower in OK condition Capacitor tested 15.2mfd (rating 15) Gas pressure 3.5 0ppm carbon monoxide present in supply duct during operation Combustion test well within nominal ranges for a healthy heat exchanger Temperature rise 38⁰ (35-65 rating) Made sure pressure switch port free of soot buildup No concerns found with this Furnace 2nd floor furnace 4yr old Trane 80% efficient single stage natural gas furnace Pulled and cleaned flame sensor Changed 16x25x1 filter Blower clean Gas pressure 3.5 0ppm carbon monoxide in ductwork or around the furnace Temperature rise 44⁰ (30-60 rating) Made sure pressure switch port is free of soot buildup No concerns found

Two system heating maintenance

Basement furnace
21yr old Trane 80% efficient single stage natural gas furnace
Pulled and cleaned flame sensor
Changed 20x25x4 filter
Blower in OK condition
Capacitor tested 15.2mfd (rating 15)
Gas pressure 3.5
0ppm carbon monoxide present in supply duct during operation
Combustion test well within nominal ranges for a healthy heat exchanger
Temperature rise 38⁰ (35-65 rating)
Made sure pressure switch port free of soot buildup
No concerns found with this Furnace

2nd floor furnace
4yr old Trane 80% efficient single stage natural gas furnace 
Pulled and cleaned flame sensor
Changed 16x25x1 filter
Blower clean
Gas pressure 3.5
0ppm carbon monoxide in ductwork or around the furnace
Temperature rise 44⁰ (30-60 rating)
Made sure pressure switch port is free of soot buildup
No concerns found Two system heating maintenance

Basement furnace
21yr old Trane 80% efficient single stage natural gas furnace
Pulled and cleaned flame sensor
Changed 20x25x4 filter
Blower in OK condition
Capacitor tested 15.2mfd (rating 15)
Gas pressure 3.5
0ppm carbon monoxide present in supply duct during operation
Combustion test well within nominal ranges for a healthy heat exchanger
Temperature rise 38⁰ (35-65 rating)
Made sure pressure switch port free of soot buildup
No concerns found with this Furnace

2nd floor furnace
4yr old Trane 80% efficient single stage natural gas furnace 
Pulled and cleaned flame sensor
Changed 16x25x1 filter
Blower clean
Gas pressure 3.5
0ppm carbon monoxide in ductwork or around the furnace
Temperature rise 44⁰ (30-60 rating)
Made sure pressure switch port is free of soot buildup
No concerns found

Nate G.

Nate G. Job Checkin

Diagnosed mini split System is definitely not cooling properly. Heat mode works but still not where it should be in the current temperatures. Recommend replacement

Diagnosed mini split
System is definitely not cooling properly.  Heat mode works but still not where it should be in the current temperatures.

Recommend replacement Diagnosed mini split
System is definitely not cooling properly.  Heat mode works but still not where it should be in the current temperatures.

Recommend replacement

Jason D.

Jason D. Job Checkin

SOLD: 10/07/2025 7:41:13 PM - Option 2 Install New Bryant HVAC System Bryant Preferred 96 2-Stage Gas Furnace Model #: 927TA48060V17A-A Serial #:4025A44017 60,000 BTU's - 96% AFUE Bryant Single-Stage Air Conditioner Model #: GA5SAN54200WABAG Serial #: 3425G12454 Ton - 15 SEER2 Coil: CVAVA4217XMAEAAA Serial #: 1425J46633 Installation: * Honeywell T6 Pro Thermostat * Aprilaire 1210 (20X25) Media Air Cleaner * New PVC furnace vents. Level 2 * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)


SOLD: 10/07/2025 7:41:13 PM - Option 2

Install New Bryant HVAC System 
Bryant Preferred 96 2-Stage Gas Furnace
Model #: 927TA48060V17A-A
Serial #:4025A44017
60,000 BTU's - 96% AFUE
Bryant Single-Stage Air Conditioner
Model #: GA5SAN54200WABAG
Serial #: 3425G12454
Ton - 15 SEER2
Coil: CVAVA4217XMAEAAA
Serial #: 1425J46633
 
Installation:
* Honeywell T6 Pro Thermostat
* Aprilaire 1210 (20X25) Media Air Cleaner
* New PVC furnace vents. Level 2
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system

Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

SOLD: 10/07/2025 7:41:13 PM - Option 2

Install New Bryant HVAC System 
Bryant Preferred 96 2-Stage Gas Furnace
Model #: 927TA48060V17A-A
Serial #:4025A44017
60,000 BTU's - 96% AFUE
Bryant Single-Stage Air Conditioner
Model #: GA5SAN54200WABAG
Serial #: 3425G12454
Ton - 15 SEER2
Coil: CVAVA4217XMAEAAA
Serial #: 1425J46633
 
Installation:
* Honeywell T6 Pro Thermostat
* Aprilaire 1210 (20X25) Media Air Cleaner
* New PVC furnace vents. Level 2
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system

Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

Jason D.

Jason D. Job Checkin

SOLD: 10/05/2025 4:13:52 PM - Option 2 Install New Bryant Air Conditioner and Coil AC: GA5SAN52400WAAA Serial #: 0225X25695 2 Ton - 15 SEER2 Coil: CVAVA2414XMAEAAA Serial #: 1325J54952 Installation: * Reconnect to existing high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system Warranty: 10 Year Bryant manufacturers Compressor Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)


SOLD: 10/05/2025 4:13:52 PM - Option 2

Install New Bryant Air Conditioner and Coil 
AC: GA5SAN52400WAAA
Serial #: 0225X25695
2 Ton - 15 SEER2 
Coil: CVAVA2414XMAEAAA
Serial #: 1325J54952
 
Installation:
* Reconnect to existing high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
 
Warranty:
10 Year Bryant manufacturers Compressor Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)


SOLD: 10/05/2025 4:13:52 PM - Option 2

Install New Bryant Air Conditioner and Coil 
AC: GA5SAN52400WAAA
Serial #: 0225X25695
2 Ton - 15 SEER2 
Coil: CVAVA2414XMAEAAA
Serial #: 1325J54952
 
Installation:
* Reconnect to existing high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
 
Warranty:
10 Year Bryant manufacturers Compressor Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

Brandon P.

Brandon P. Job Checkin

Electric heating preventative maintenence inspection on two Bryant geothermal units. Replaced both 30x36x2 air filters. Test ran operation of electric heat strips, and geothermal heating. Humidifier pads in new condition. All systems are operating properly, efficiently, and ready for Winter.


Nate G.

Nate G. Job Checkin

Furnace number 1 failed combustion test, indicates failed heat exchanger. 23 years old Furnace needs replaced 5 system heating maintenance Third floor system (#5) Cleaned flame sensor Blew out trap Gas pressure 3.5 for high fire and 1.7 for low fire Temp rise 63⁰ Filter clean Electronic portion of the air cleaner has failed Replacement parts are discontinued Humidifier pad looks unused Found humidifier not functional Diagnosed failed humidistat System has a Honeywell VisionPro8000 thermostat capable of humidifier control Wired humidifier to the thermostat. Also wired both heat stages to the thermostat for better system control. Master bedroom system (#4) Replaced filter The filter cabinet has been installed in the wrong orientation since day 1. Will need Uninstalled and flipped or replaced. Humidifier water panel looks unused Also found this humidifier non-functional Wired to the thermostat and verified proper operation Gas pressure 3.5 and 1.6 Temp rise 35 Cleaned flame sen

Furnace number 1 failed combustion test, indicates failed heat exchanger.  23 years old
Furnace needs replaced

5 system heating maintenance 

Third floor system (#5)
Cleaned flame sensor
Blew out trap
Gas pressure 3.5 for high fire and 1.7 for low fire
Temp rise 63⁰
Filter clean
Electronic portion of the air cleaner has failed
Replacement parts are discontinued 
Humidifier pad looks unused
Found humidifier not functional
Diagnosed failed humidistat
System has a Honeywell VisionPro8000 thermostat capable of humidifier control
Wired humidifier to the thermostat. 
Also wired both heat stages to the thermostat for better system control. 

Master bedroom system (#4)
Replaced filter
The filter cabinet has been installed in the wrong orientation since day 1.  Will need Uninstalled and flipped or replaced.
Humidifier water panel looks unused
Also found this humidifier non-functional 
Wired to the thermostat and verified proper operation 
Gas pressure 3.5 and 1.6
Temp rise 35
Cleaned flame sen Furnace number 1 failed combustion test, indicates failed heat exchanger.  23 years old
Furnace needs replaced

5 system heating maintenance 

Third floor system (#5)
Cleaned flame sensor
Blew out trap
Gas pressure 3.5 for high fire and 1.7 for low fire
Temp rise 63⁰
Filter clean
Electronic portion of the air cleaner has failed
Replacement parts are discontinued 
Humidifier pad looks unused
Found humidifier not functional
Diagnosed failed humidistat
System has a Honeywell VisionPro8000 thermostat capable of humidifier control
Wired humidifier to the thermostat. 
Also wired both heat stages to the thermostat for better system control. 

Master bedroom system (#4)
Replaced filter
The filter cabinet has been installed in the wrong orientation since day 1.  Will need Uninstalled and flipped or replaced.
Humidifier water panel looks unused
Also found this humidifier non-functional 
Wired to the thermostat and verified proper operation 
Gas pressure 3.5 and 1.6
Temp rise 35
Cleaned flame sen

Nate G.

Nate G. Job Checkin

Performed heating maintenance on a Daikin heat pump system and a Bryant electric air handler Changed 20x25x4 and 16x25x4 filters with ones we provide Inspected wiring for electric heat kits No signs of overheated connections Wires all tight and secure Amp draw on heating elements was within spec Heat pump indoor and outdoor coils are clean Capacitor tested in specification for heat pump Tested defrost function to verify proper operation Only issue found is a broken drain line for the attic system. Water is collecting in the emergency drain pan, so nothing is leaking into the ceiling. This does need fixed to prevent the drain pan rusting out completely and then leaking. Sent proposal to make that repair.

Performed heating maintenance on a Daikin heat pump system and a Bryant electric air handler
Changed 20x25x4 and 16x25x4 filters with ones we provide
Inspected wiring for electric heat kits
No signs of overheated connections 
Wires all tight and secure
Amp draw on heating elements was within spec
Heat pump indoor and outdoor coils are clean
Capacitor tested in specification for heat pump
Tested defrost function to verify proper operation 

Only issue found is a broken drain line for the attic system.  Water is collecting in the emergency drain pan, so nothing is leaking into the ceiling.  This does need fixed to prevent the drain pan rusting out completely and then leaking. 
Sent proposal to make that repair. Performed heating maintenance on a Daikin heat pump system and a Bryant electric air handler
Changed 20x25x4 and 16x25x4 filters with ones we provide
Inspected wiring for electric heat kits
No signs of overheated connections 
Wires all tight and secure
Amp draw on heating elements was within spec
Heat pump indoor and outdoor coils are clean
Capacitor tested in specification for heat pump
Tested defrost function to verify proper operation 

Only issue found is a broken drain line for the attic system.  Water is collecting in the emergency drain pan, so nothing is leaking into the ceiling.  This does need fixed to prevent the drain pan rusting out completely and then leaking. 
Sent proposal to make that repair.

Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 16x25x1 new today Clean flame sensor Ohm test igniter: 52.2 Pull and flush drain trap Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today owner supply Inspect exhaust flu - no concerns 2” pvc Set thermostat for heat Check amp draw on blower motor: 9.3 start 6.2 idle Check amp draw on inducer motor:0.49 Check delta T - 60° Furnace is in optimal running conditions


Brandon P.

Brandon P. Job Checkin

2003 Bryant R-22 AC system was operating in cooling mode upon arrival. Indoor blower is operating and thermostat is operating. Inspection of outdoor unit showed that compressor is running but condenser fan motor is not. Compressor was making louder than usual noise while running. Entire system was very hot to the touch. Service disconnect was very hot aswell. Pulled disconnect and used garden hose to cool system down to safe temperatures. Once cooled down, inspection of electrical components showed that 55/5UF capacitor is reading 12/0uf. This explains why the compressor was running, and creating excess heat, and why the condenser fan motor was not operating. Replaced with new 55/5uf capacitor setup and test run operation. Compressor and fan motor come on as they should. Compressor is no longer making unusual noises. Refrigerant lines carry a normal temperature. Did not check refrigerant pressures as there are no issues suspected. System is operating in cooling at this time. Due to age

2003 Bryant R-22 AC system was operating in cooling mode upon arrival. Indoor blower is operating and thermostat is operating. Inspection of outdoor unit showed that compressor is running but condenser fan motor is not. Compressor was making louder than usual noise while running. Entire system was very hot to the touch. Service disconnect was very hot aswell. Pulled disconnect and used garden hose to cool system down to safe temperatures. Once cooled down, inspection of electrical components showed that 55/5UF capacitor is reading 12/0uf. This explains why the compressor was running, and creating excess heat, and why the condenser fan motor was not operating. Replaced with new 55/5uf capacitor setup and test run operation. Compressor and fan motor come on as they should. Compressor is no longer making unusual noises. Refrigerant lines carry a normal temperature. Did not check refrigerant pressures as there are no issues suspected. System is operating in cooling at this time. Due to age 2003 Bryant R-22 AC system was operating in cooling mode upon arrival. Indoor blower is operating and thermostat is operating. Inspection of outdoor unit showed that compressor is running but condenser fan motor is not. Compressor was making louder than usual noise while running. Entire system was very hot to the touch. Service disconnect was very hot aswell. Pulled disconnect and used garden hose to cool system down to safe temperatures. Once cooled down, inspection of electrical components showed that 55/5UF capacitor is reading 12/0uf. This explains why the compressor was running, and creating excess heat, and why the condenser fan motor was not operating. Replaced with new 55/5uf capacitor setup and test run operation. Compressor and fan motor come on as they should. Compressor is no longer making unusual noises. Refrigerant lines carry a normal temperature. Did not check refrigerant pressures as there are no issues suspected. System is operating in cooling at this time. Due to age

seth p.

seth p. Job Checkin

Service maintenance warranty Library system located in the garage attic has a thermostat installed by Vivint that is not functioning correctly and/or installed properly for DUAL FUEL operation. The thermostat is not energizing gas heat through the isolation relay at the furnace. The black wire was removed from the original thermostat but not installed on the new thermostat. ( E heat?) Outdoor temperature heat pump lock out and change over temperatures are unknown This thermostat does not appear to be able to control emergency heat separate from heat pump or AUX Homeowners must contact Vivint or choose a dual fuel compatible thermostat for Westin Air to install


seth p.

seth p. Job Checkin

Seth cell 614-394-3279 Three system heating equipment multi-stage geothermal package, geothermal split, dual fuel split. 2 x attic air handlers, one basement Waterfurnace Envision package system All geothermal split and package systems are running in good condition requiring little maintenance after the move-in inspections and major overhaul cleanings performed a few months ago. Both geothermal air filters are in like new very good condition with no service required Test run multi-stage heat pump and all auxiliary electric resistance heat Both geothermals are in very good condition Over the garage system is 33 years old this season original to the house in 1992. The single stage Lennox r22 heat pump turned on and produced good warm air in heat pump mode but failed to initiate the gas furnace in auxiliary emergency heat mode on the Vivint control system electrical diagnostics determined that the thermostat is not producing a W signal with a call for auxiliary emergency heat. Dur


seth p.

seth p. Job Checkin

Upon arrival today the powered attic exhaust fan was venting completely clearing the attic of any heat and possible gas fumes or build up. Electronic testing followed by micro leak gel confirmed a steady stream of natural gas leakage at the threaded joint of the half inch stopcock Shut down attic supply line at the 1-in tap in the basement Replace half inch stop valve on attic Repressurize and retest with electronic All equipment is ready for full service. Power was never interrupted and thermostat settings were never changed


Graham M.

Graham M. Job Checkin

Remove side panels and wash coil from inside out due to heavy dirt/dust buildup on spinefin coil. Replace dual run 40+5 capacitor due to old reading 40.2+3.5 fan circuit fallen below spec Test run operation after cleaning and replacing capacitor, no concerns unit is cooling with no issues at this time.


Graham M.

Graham M. Job Checkin

Install electric unit heater in basement wall


Jason D.

Jason D. Job Checkin

Install New Bryant Air Conditioner and Coil AC: GA5SAN53600W Serial #: 2325X17589 3 Ton 14.3 SEER2 - Single-Stage Puron Advance Refrigerant, R-454B 208/230 Volt, 1 Phase Coil: ADP-GG8JA36D175B1805R Serial #: 7125D08928 Installation: *Reuse existing thermostat *Reconnect to existing high voltage electric *Transition to existing supply and return ductwork *Reuse existing plenum evap case. *Start up and commission new system *Replace parts warranty circuit board on existing Warranty: 10 Year Bryant manufacturers Compressor Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)